House Wiring Cables

Geoelis House Wiring Cables

PVC INSULATED SINGLE-CORE COPPER CABLES 0.6/1KV

Type: NCG

Specification: Bs 6004, NIS 172

Application: for use in housing, offices, factories, switch board, distribution boards, conduit, on or under plaster.

Note: maximum permissible conductor temperature under service condition is taken at 70oc. maximum current rating in pipe is considered at ground temperature of 35oc. maximum current rating in air is considered at a temperature of 40oc

Nominal cross sectional area mm2 Conductor number x diameter of wire mm Radial Thickness of Insulation mm Nominal overall diameter mm Maximum Current rating A ------ in pipe -------- in air Weight kg/standard length kg Standard Delivery length m Delivery form
0.5RW
1 X 0.80
0.6
2.0
5
7
0.80
100
Coil
0.75RW
1 X 0.98
0.6
2.2
7
13
1.10
100
Coil
1.0RW
1 X 1.13
0.7
2.8
13
21
1.82
100
Coil
1.5RW
1 X 1.38
0.7
2.8
13
21
1.82
100
Coil
2.5RW
1 X 1.78
0.8
3.2
17
28
3.50
100
Coil
4RW
1X 2.25
0.8
3.9
22
37
4.54
100
Coil
6RW
1 X 2.76
0.8
4.4
29
48
6.50
100
Coil
10RS
7 X 1.35
1.0
6.1
39
64
11.42
100
Coil
16RS
7 X 1.70
1.0
7.1
53
85
17.33
100
Coil
25RS
7 X 2.14
1.2
8.8
72
112
27.25
100
Coil
35RS
7 X 2.52
1.2
10.0
90
138
369.00
1000
TWD 8
50RS
19 X 1.78
1.4
11.7
115
172
495.00
1000
TWD 10
70RS
19 X 2.14
1.4
13.5
114
213
670.00
1000
TWD 10
95RS
19 X 2.52
1.6
15.8
172
254
967.00
1000
TWD 12
120RS
37 X 2.03
1.6
17.4
205
300
1204.00
1000
TWD 12
150RS
37 X 2.25
1.8
19.4
----
340
1481.00
1000
TWD 12
185RS
37 X 2.52
2.0
21.6
----
390
1857.00
1000
TWD 12
240RS
61 X 2.25
2.2
24.7
----
460
2429.00
1000
TWD 12
300RS
61 X 2.52
2.4
27.5
----
530
1520.00
500
TWD 12
400RS
61 X 2.85
2.6
30.9
----
631
1937.00
500
TWD 14
500RS
61 X 3.20
2.8
34.4
----
722
2433.00
500
TWD 14
630RS
91 X 2.97
2.8
38.3
----
970
3100.00
500
TWD 16

FLAT TWIN-CORE PVC INSULATED AND SHEATED COPPER CABLES 300/500V

SPECIFICATION: DIN 48201

APPLICATION: For use in earthen electrical installations, in lightening protection and for overhand lines distribution systems

NOTE: Maximum conductor temperature under service condition is taken as 70o/c. maximum current rating in air is considered at a temperature of 40o/c.

Nominal cross sectional area mm2 Conductor number x diameter of wire mm Radial Thickness of Insulation mm Radial Thickness of Sheath mm Nominal overall diameter --- Minimum mm Nominal overall diameter --- Maximum mm Maximum Current rating A ------ in pipe Weight kg/standard length kg Standard Delivery length m Delivery form
1.0RW
1 X 1.13
0.7
0.9
6.2 X 4.0
7.4 X 4.7
14
4.8
100
Coil
1.5RW
1 X 1.38
0.7
0.9
7.0 X 4.4
8.4 X 5.4
17
6.4
100
Coil
2.5RW
1 X 1.78
0.8
1.0
8.4 X 5.2
9.8 X 6.2
24
9.6
100
Coil
4RW
1 X 2.25
0.8
1.0
9.6 X 5.6
11.5 X 2.2
31
13.0
100
Coil
6RW
1 X 2.75
0.8
1.1
10.5 X 6.4
13.0 X 8.0
40
17.9
100
Coil
10RW
7 X 1.35
1.0
1.2
13.0 X 7.8
16.0 X 9.6
56
30.3
100
Coil
16RW
7 X 1.70
1.0
1.3
15.5 X 9.0
18.5 X 11.0
74
44.1
100
Coil